Descrizione
La Vesda VLF di Xtralis è un rilevatore di fumo aspirante ideale per piccoli spazi critici per le imprese. Disponibile in due modelli, il VLF-500 copre le aree fino a 500 m2 (5.380 piedi quadrati).
- Installazione e messa in servizio out-of-the-box
- Sensing a flusso d'aria ad ultrasuoni
- Rilevamento assoluto di fumo a base laser
- Progetti di rete di tubi pre-ingegnerizzati
- Soglie di allarme programmabili
- Pulisci protezioni ottiche della barriera d'aria
- Display di riconoscimento istantaneo
- Finder istantaneo di guasto ™
- Fumo autolearn ™
- Flusso Autolearn ™
- Porta di accesso al servizio di campo
- Registrazione di eventi multipli (in registri separati), fino a 18.000 eventi
- Funzionalità di configurazione offline/online
Fogli dati
Datasheet
You may also like
Recently viewed
VESDA VLF-500 FAQs
The VESDA VLF-500 LaserFOCUS aspirating smoke detector is a compact aspirating fire detection system designed to provide very early warning smoke detection in small to medium environments. The detector continuously samples air through a pipe network and analyses it using laser-based smoke detection technology to identify smoke particles at extremely low concentrations.
The VESDA VLF-500 is designed to protect areas of up to 500 m², depending on pipe design and sampling hole configuration. Correct system design should always follow the VESDA VLF-500 installation manual and manufacturer guidelines.
The primary difference between the VESDA VLF-250 and VESDA VLF-500 is the size of the protected area.
VESDA VLF-250 – coverage up to 250 m²
VESDA VLF-500 – coverage up to 500 m²
Both models use LaserFOCUS aspirating smoke detection technology and provide very early warning fire detection.
The VESDA VLF-500 aspirating smoke detector draws air continuously through a sampling pipe and analyses it inside a laser detection chamber. This laser smoke detection technology allows the system to identify smoke particles long before visible smoke develops.
The VESDA VLF-500 is commonly used in environments where early fire detection is critical, including:
Server rooms and data infrastructure spaces
Electrical switch rooms
Telecommunications facilities
Control rooms and monitoring centres
Equipment cabinets and plant rooms
These environments benefit from very early warning aspirating smoke detection.
The VESDA VLF-500 manual, installation guide and product documentation are available from the manufacturer or via the documentation section on this page. These resources provide guidance on installation, pipe network design, configuration and commissioning.
What is the VESDA LaserFOCUS series?
Any question?
If we still haven't answered your question, you can contact us below and we will get back to you as soon as possible.